Foams
One-component polyurethane foam FIRE RESISTANT - max class EI 240 (EN 13501-2), with safety gloves
Emicode Plus
|
Code |
Contents |
Usage |
Finish |
Pcs. per carton |
Pcs. per pallet |
|
|---|---|---|---|---|---|---|
| BRF 03 00 750 | manuale |
|
12 | 468 |
For filling, insulation and installation operations where high fire resistance is required (up to 240 minutes).
EMICODE® EC1 Plus certified, with very low VOC (volatile organic compound) emissions.
Sultable lor insulating and sealing joints in fire rated walls, installation of fire-proof doors and windows, can also be used to fill gaps between walls, door and window frames, piping and electrical installations. The foam cures with air humidity, ensures strong bond and thermal insulation once cured and provides a good adhesion to most common building materials such as wood, concrete, cellular concrete, brick, metals, glass and aluminium.
Paintable once dry. It does noi adhere on PE, PP, PTFE and silicon.
HOW TO USE: Preparation - Clean and degrease surfaces and moisten them. The can temperature should be 20-25°C. Shake the can before use. Remove the protective cover and screw on the nozzle with the tube. Appllcation - Keep the can upside down, vertically, during the application. The volume of the foam expands after application by 2-3 times.The hardened foam is protected from the UV radiations. lf the can is noi used in full, clean the can and tube. After curing, remove excess foam mechanically (e.g. with a cutter). Cleaning - Fresh foam can be cleaned with the special BRP 01 TECFI Cleaner.
Store cans in upright position.